Cerex UV3000 Series
A collection of UV-DOAS process and stack gas analyzers customizable for almost any application
Based around a proven UVDOAS data acquisition system, each unit is capable of harnessing our proven methods in your environment. Available in Cross Stack, Rackmount, Probe and Zone configurations, the UV 3000 series of analyzers has something for everyone. Choice of materials, sampling pumps, and sample cells are a few options available to the adaptation of the UV 3000.
Our UV3000 analyzers accurately measure common combustion gases, BTEX, SVOC’s, chlorine, ammonia, sulfur dioxide, and many more. All our devices feature custom alarms, complete integration into your existing data network, and an unparalleled ease of use.
- Part-per-billion (ppb) level detection limits
- Simultaneous multi-gas capability
- Greater performance than electrochemical and PID technology at a low cost

Cerex UV3000 Series
Stack Analyzers


UV3000-P
Probe
Point UV-DOAS multi-gas analyzer equipped with a sampling probe to perform in-situ process and chimney measurements when shorter path lengths and/or particulate filtering are required. Typically for CEM, DeSOx, DeNOx.
General
Measurements | 63.5cm x 54.1cm x 47.25cm |
(25in x 21.3in x 18.6in) | |
Probe Length | 0.1 – 1.5 meters Application Specific |
Weight | 66kg (145lbs) |
Material | Stainless Steel |
UV3000-CS
Cross Stack
Complete insitu solution to monitor critical stack emissions such as Ammonia (NH3), BTEX, Nitrogen Oxides (NOx), and more. Eliminates equipment and maintenance associated with extracting sample from stack.
General
Measurements | 63.5cm x 54.1cm x 47.25cm |
(25in x 21.3in x 18.6in) | |
Weight | 66kg (145lbs) |
Material | NEMA 4/4X |
Process Analyzers

UV3000-CRM
Rackmount
Designed to provide high performance analysis for a variety of applications such as Process, Ambient, and Continuous Emission Monitoring in a rack mount configuration
General
Measurements | 63.5cm x 54.1cm x 47.25cm |
(25in x 21.3in x 18.6in) | |
Weight | 66kg (145lbs) |
Material | Stainless Steel |
Zone Monitoring

UV3000
Multiplexed
Designed to provide multi-zone monitoring of critical gases, such as Benzene (C6H6) Butadiene (C4H6), Hydrogen Sulfide (H2S) within a single analyzer
General
Measurements | 50.8 x 63.5 x 34cm |
(20”x 25” x 13.4”)* | |
Weight | 66kg (145lbs) |
Material | Stainless Steel |

How it Works
UV-DOAS Technology
Within each Cerex UV3000 analyzer, a gas sample is drawn in and measured in a fiber coupled external cell connected to a process stream, or via an optional sample pump.
A miniature spectrometer then collects the gas fingerprint data, and Cerex’s proprietary software compares the results to a calibrated reference, or “library spectra”.
Ultimately, an onboard or external PC reports reliable real‐time concentration data up to once per second, and stores all spectral data for later post processing or archiving.
The result is near real-time spectral “fingerprints” of all target compounds, with accurate qualitative and quantifiable data of each.
How is this possible? A physics principle known as the Beer-Lambert Law. UV radiation that passes through a gas will “absorb” the gas; thus, when viewed on a spectrograph, a distinct pattern of absorption appears. Each gas has a unique “absorption pattern”, and this, combined with our proprietary photometric Differential Optical Absorption Spectroscopy (DOAS) algorithm, Cerex UV-DOAS analyzers are able to quickly and accurately identify compounds from an air mixture without the need to calibrate or take a clean air background.
Why UV-DOAS?
Ultraviolet spectroscopy principles are similar to common infrared methods, but offer lower detection capability for many chemicals associated with impact on human health. We recommend UV-DOAS based analyzers for a faster, more accurate, and less costly solution for certain compounds and applications.

Common Detectable Gases
Ultra Low Detection Limits
The Cerex Hound Series has as low as parts-per-billion minimum detection limits and wide dynamic ranges, allowing earlier and more thorough detection of gases than traditional sensor arrays. In comparison to outdated technologies, UV3000 series analyzers feature multi-gas monitoring of individual species, lower detection limits, no water vapor interference, inherent calibration and no sensors to poison.
Inherent Calibration
The system can be span checked at any time, however, the measurement and analysis method employed in this system has the true calibration inherent in the fixed library references. Unless there is a system fault, calibration is never needed. The system is self‐compensating for all normal sources of drift found in analyzers including temperature, aging of the lamp, degradation of the optics, etc.
Targeted Library for Increased Value and Cost-Effectiveness
Cerex UV3000 analyzers include a multi-purpose standard library suitable for monitoring dozens of compounds. Custom calibrations are available based on application.
UV3000 Common Target Gases
1,3 Butadiene C4H6 |
Acetaldehyde C2H4O |
Acetone CH3COCH3 |
Acrolein C3H4O |
Ammonia NH3 |
Benzene C6H6 |
Bromine Br2 |
Carbon Disulfide CS2 |
Chlorine Cl2 |
Chlorine Dioxide ClO2 |
Ethyl Benzene C8H10 |
Ethane C2H6 |
Ethanol C2H6O |
Ethene C2H4 |
Formaldehyde CH2O |
Hydrogen Sulfide H2S |
Isoprene C5H8 |
Mercury Hg |
Naphthalene C10H8 |
Nitric Oxide NO |
Nitrogen Dioxide NO2 |
Nitrous Acid HNO2 |
Nitric Acid HONO2 |
Nitrous Oxide N2O |
Oxygen O2 |
Ozone O3 |
Phosgene COCl2 |
Phenol C6H5OH |
Styrene C8H8 |
Sulfur Dioxide SO2 |
Sulfur Trioxide SO3 |
Toluene C7H8 |
Trimethylbenzene C9H12 |
O-Xylene, M-Xylene, P-Xylene C8H10 |
*NOTE: For detection of gaseous compounds not available within the UV spectrum, we recommend the Cerex FT5000 Series – fixed-installation analyzers that use FTIR (Fourier Transform Infrared).

Software
Results You Can Rely On
Cerex recognizes that detailed gas monitoring results need to be reliable and available quickly to various stakeholders. Consequently, Cerex engineers developed software to accurately detect and display gases within the air, in real-time, from any location.
On a Cerex UV3000 analyzer, a user can see results on the analyzer itself, or remotely via a phone, tablet, or computer anywhere in the world via a virtual connection. GPS and cellular configurations make this possible in isolated environments.
All data is automatically saved in an easy to access .csv file; this feature helps our clients in various ways - from daily use to crucial events such as evidence in court. Early detection translates into quicker response times, reduced environmental impact, decreased plant downtime, and reduced exposure to site personnel and the community.

Real time spectral subtraction and synthetic background implementation allow the UV Hound and Micro Hound to clearly display accurate concentrations of target gases over 1000 meters without interference from other gas species



Applications
Serving clients in a variety of industries
Common applications for the UV3000 include measuring Ammonia (NH3), Chlorine (CL2), Sulfur Dioxide (SO2), and BTEX amongst many more. The UV3000 comes in a NEMA4 rated enclosure for outdoor environments, or a 19 inch rack mount enclosure.
All Applications
Continuous Emissions Monitoring
Extractive Hot/Wet or Cool/Dry
DeSOx, DeNOx, Ammonia Slip Monitoring
Process Monitoring
Ambient Air Monitoring

Downloads
Coming Soon